Response Electronics CL6011B Especificaciones Pagina 59

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 170
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 58
4-29Input and Output Cards
Original — December 1991 UM4.6:CS6003
Table 4-16. Switch Settings on BLH Weigh Scale Models 4310A and
4315A
(1)
Switch
(2)
Position Setting Description
SW1 1 OFF 2 stop bits
2 OFF Even parity
3 OFF 9600 baud
4 ON ––
5 ON ––
6 ON ––
7 ON 20 mA comms mode
8 OFF ––
SW2 1 ON Xmit on demand
2 OFF Xmit on motion and overload conditions
3 OFF ––
4 OFF ––
1. Switches and positions not listed in this table do not affect weigh scale interface operation.
2. Switches are located on the BLH scale option 10 board and not the main board.
The data format for the BLH scales is 11 bit ASCII, 1 start bit, 7 data bits,
even parity, and 2 stop bits at 9600 baud.
Note
The BLH LCp-10 requires a custom EPROM from
BLH to interface to the weigh scale interface card.
The custom LCp-10 uses the same protocol as
the Teledo scale. This requires the weigh scale
interface card to be set for the Teledo mode.
Table 4-17. Masstron Model M5000 Jumper Position
(1)
Jumper Description Required Position Explanation
JU3 Baud Rate 1 (top) 4800 baud
JU7 Comp Xmit ON Active
JU8 Comp Xmit ON Active
JU13 (old style) Clear to Send OFF (open) Disabled
JU13 (new style) 20mA/RS-232 20 mA 20 mA
1. Jumpers not included in this table do not apply to interface card use.
The data format for the Masstron Model M5000 is 10 bit ASCII, 1 start
bit, 8 data bits, no parity, and 1 stop bit at 4800 baud.
4
Vista de pagina 58
1 2 ... 54 55 56 57 58 59 60 61 62 63 64 ... 169 170

Comentarios a estos manuales

Sin comentarios