4-27Input and Output Cards
Original — December 1991 UM4.6:CS6003
X00613–A
PS1
S1
S2
Figure 4-9. Weigh Scale Interface Card
The 8-position DIP switch S1 is the scale capacity switch used to set the
scale range. Switch positions 1 through 4 of S1 sets the range for weigh
scale number 1 and switch positions 5 through 8 of S1 sets the range for
weigh scale number 2. Table 4-13 shows the switch settings for each
range.
Table 4-13. Weigh Scale Interface Card Range Switch Settings
For Weigh Scale No. 1 For Weigh Scale No. 2
S1 Switch Position S1 Switch Position
Scale
Range
1 2 3 4 5 6 7 8
Not used OFF OFF OFF OFF OFF OFF OFF OFF
0-50 ON OFF OFF OFF ON OFF OFF OFF
0-100 OFF ON OFF OFF OFF ON OFF OFF
0-300 ON ON OFF OFF ON ON OFF OFF
0-500 OFF OFF ON OFF OFF OFF ON OFF
0-1000 ON OFF ON OFF ON OFF ON OFF
0-2000 OFF ON ON OFF OFF ON ON OFF
0-3000 ON ON ON OFF ON ON ON OFF
0-5000 OFF OFF OFF ON OFF OFF OFF ON
0-10000 ON OFF OFF ON ON OFF OFF ON
0-20000 OFF ON OFF ON OFF ON OFF ON
0-30000 ON ON OFF ON ON ON OFF ON
0-50000 OFF OFF ON ON OFF OFF ON ON
0-100000 ON OFF ON ON ON OFF ON ON
0-200000 OFF ON ON ON OFF ON ON ON
Not used ON ON ON ON ON ON ON ON